Sonus SBC1000 Release 3.1 EuroISDN improvements

ISDN Facility Message Analysis Support

In Release 3.0 the SBC 1000/2000 gateway supported sending and retrieving the redirecting number carried in the facility element when connecting to PBX using QSIG switch variant. Beginning with Release 3.1, the SBC 1000/2000 gateway applies these functions to the EuroISDN variant based on ETS 300 207-1 and ETS 300 196-1 standards. This feature capability allows making routing decisions based on the redirecting number provided by PSTN through a Facility element.